MARATTO

article · RSC Advances

Voltammetric and impedimetric determinations of selenium(<scp>iv</scp>) by an innovative gold-free poly(1-aminoanthraquinone)/multiwall carbon nanotube-modified carbon paste electrode

202218 citationsOpen accessKafr el-Sheikh University

Abstract

Selenite (Se<sup>4+</sup>), a significant source of water pollution above the permissible limits, is considered a valuable metal by environmentalists. In this study, we described a novel electrochemical sensor that utilized a carbon paste electrode (CPE) that was modified using multiwall carbon nanotubes (MWCNTs) and poly(1-aminoanthraquinone) (p-AAQ) for finding Se<sup>4+</sup> in water samples. Electrochemical quantification of Se<sup>4+</sup> depends on the formation of a selective complex (piaselenol) with p-AAQ. In this work, we prepared a CPE modified by physical embedding of MWCNTs and 1-aminoanthraquione (AAQ), while the polymer film was formed by anodic polymerization of AAQ by applying a constant potential of 0.75 V in 0.1 M HCl for 20 s followed by cyclic voltammetry (CV) from -0.2 to 1.4 V for 20 cycles. The modified CPE was used for differential pulse voltammetry (DPV) of Se<sup>4+</sup> in 0.1 M H<sub>2</sub>SO<sub>4</sub> from 0 to 0.4 V with a characteristic peak at 0.27 V. Further, the proposed sensor was characterized by scanning electron microscopy, energy-dispersive X-ray spectroscopy, and electrochemical impedance spectroscopy (EIS). The analytical conditions regarding the electrode performance and voltammetric measurements were optimized, with the accumulation time and potential, supporting electrolyte, differential-pulse period/time, and amplitude. The EIS results indicated that the p-AAQ/MWCNTs-modified CPE sensor (p-AAQ/MWCNTs/CPE) that also exhibited low charge-transfer resistance (<i>R</i> <sub>ct</sub>) toward the anodic stripping of Se<sup>4+</sup>, exhibited good analytical performance toward different concentrations of Se<sup>4+</sup> in a linear range of 5-50 μg L<sup>-1</sup> Se<sup>4+</sup> with a limit of determination (LOD) of 1.5 μg L<sup>-1</sup> (3<i>σ</i>). Furthermore, differential-pulse voltammetry was employed to determine different concentrations of Se<sup>4+</sup> in a linear range of 1-50 μg L<sup>-1</sup> Se<sup>4+</sup>, and an LOD value of 0.289 μg L<sup>-1</sup> was obtained. The proposed sensor demonstrated good precision (relative standard deviation = 4.02%) at a Se<sup>4+</sup> concentration of 5 μg L<sup>-1</sup>. Moreover, the proposed sensor was applied to analyze Se<sup>4+</sup> in wastewater samples that were spiked with Se, and it achieved good recovery values.

Research topics

  • Electrochemical Analysis and Applications
  • Electrochemical sensors and biosensors
  • Mercury impact and mitigation studies

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.1039/d1ra07588h

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.