Validating Field-Feasible Measures of Recent Khat Use: A Diagnostic Accuracy Study Comparing Amphetamine Immunoassay and Assisted Self-Report Against HPLC in an Ethiopian Male Cohort

2026Open accessJimma University

Abstract

Abstract Background Khat ( Catha edulis) is a widely consumed natural amphetamine-analog used across East Africa and the Arabian Peninsula. Accurate field-feasible measurement of recent khat use is a prerequisite for large-scale epidemiological research; yet no validated alternatives to laboratory reference methods have been identified in the scientific literature. This nested validation study evaluated the diagnostic accuracy of two point-of-care measures, a commercial amphetamine immunoassay and a Timeline Followback (TLFB) Assisted Self-Report (ASR), against high-performance liquid chromatography (HPLC) quantification of urinary norephedrine (NE), while additionally assessing agreement between the two field measures. Methods A prospective, random sub-sample of 119 male participants aged 18-40 years from the Gilgel Gibe Field Research Center (GGFRC) longitudinal cohort, Ethiopia (validation timepoint T2, 2015), was used. Three index-reference comparisons were conducted: (1) amphetamine immunoassay (nal von minden, Drug-Screen AMP test, 300Öng/mL cutoff) vs.ÖHPLC; (2) binary ASR (past-week use) vs.ÖHPLC; and (3) binary ASR vs.Öimmunoassay. Sensitivity (positive percent agreement, PPA), specificity (negative percent agreement, NPA), positive predictive value (PPV), negative predictive value (NPV), overall accuracy (overall percent agreement, OPA), and Cohen’s kappa were calculated with 95% confidence intervals. Pre-specified secondary analyses applied three pharmacokinetically-informed recall windows (0-2, 3-5, and 6-7 days prior to interview) to ASR. Results Against HPLC (77 positive, 42 negative), the immunoassay showed perfect specificity (1.0 [0.916-1.0]) and PPV (1.0 [0.91-1.0]) but low sensitivity (0.52 [0.40-0.64]), NPV (0.53 [0.42-0.65]), overall accuracy (0.69 [0.60-0.77]), and weak kappa (0.43 [0.34-0.52]). Binary ASR showed high sensitivity (0.96 [0.89-0.99]), specificity of 0.60 [0.433-0.74], PPV (0.81 [0.72-0.89]), NPV (0.89 [0.72-0.98]), with overall accuracy 0.83 [0.75-0.89] and moderate kappa (0.60 [0.51,0.69]). Restricting ASR to use within 0-2 days improved specificity to 0.69 [0.52-0.84], PPV to 0.86 [0.77-0.93], overall accuracy to 0.87 [0.79-0.93], and kappa to 0.69 [0.61-0.78] (moderate), while sensitivity (0.96 [0.89-0.99]) and NPV (0.89 [0.72-0.98]) remained stable. Against the immunoassay, ASR achieved high PPA of (1.0 [0.91-1.0]), NPA of 0.35 [0.25-0.47], OPA of 0.57 [0.48-0.66], and minimal kappa (0.27 [0.19-0.35]). Conclusions Time-stratified ASR (0-2 days) is a valid, scalable alternative to biological testing for recent khat use in resource-limited settings. The immunoassay’s 300 ng/mL cutoff functions as a marker of heavy or recent high-dose khat use rather than any-use detection. Its perfect specificity and PPV make it valuable as a confirmatory test for substantial exposure, while its lower sensitivity reflects calibration to amphetamine rather than to khat-derived cathinone metabolite. Registration Not registered.

Research topics

  • Forensic Toxicology and Drug Analysis
  • Psychedelics and Drug Studies
  • Substance Abuse Treatment and Outcomes

Sustainable Development Goals

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.64898/2026.06.14.26355466

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.