article · MANUFACTURING TECHNOLOGY
This paper aims to study the efficiency of using prefabricated layers made from plain cementitious composite materials for enhancing the flexural behavior of reinforced concrete (RC) continuous beams. The strengthening system was applied at 20 mm thickness, 150 mm width, and adequate development length. The prefabricated layers were placed in the tension cover in the positive and negative zones. All beams have the same geometric dimensions and positive and negative steel reinforcement ratios. The results showed that the prefabricated layer was deformed with the RC specimen without debonding, which enhanced the cracking patterns and distributed the crack width. A slight improvement in the strengthened beam capacity was 7% for the yielding load and 6% for the ultimate load. The energy absorption capacity of the strengthened beam decreased by 30.67%, whereas both beams achieved the same ductility index.
This page summarises published work. The authoritative version sits with the publisher.
DOI: 10.21062/mft.2024.071
Is something wrong with this record? Report it or request removal.
Discussion
Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.
No discussion yet. Open the first thread.
New to MARATTO™? Create a free account.