MARATTO

article · Materials

The Influence of Ferrule Design and Pulpal Extensions on the Accuracy of Fit and the Fracture Resistance of Zirconia-Reinforced Lithium Silicate Endocrowns

202413 citationsOpen accessMansoura University

Abstract

The study aimed to assess the marginal, axial, and internal adaptation, as well as the fracture resistance of zirconia-reinforced lithium silicate (ZLS) endocrowns with varying pulpal inlay extensions and marginal geometry. Sixty extracted maxillary first molar teeth were divided into six groups (n = 10) according to pulpal inlay extension and marginal configuration. The first three groups (J2, J3, and J4) utilized prepared teeth for endocrowns without ferrule design and 2 mm, 3 mm, and 4 mm pulpal extensions, respectively. The second three groups (F2, F3, and F4) utilized prepared teeth with 1 mm shoulder margins and 2 mm, 3 mm, and 4 mm pulpal extensions. The endocrowns were fabricated from ZLS blocks using CAD/CAM milling technology. After cementation, the specimens underwent thermal aging for 5000 cycles and were evaluated for marginal adaptation. Using a universal testing machine, the fracture resistance was tested under quasistatic loading (1 mm/min). Two-way ANOVA and the Tukey’s post hoc test were employed for data analysis (p ≤ 0.05). The results of this study revealed that endocrowns without ferrule exhibited superior fracture strength than a 1 mm ferrule design p < 0.05, irrespective of the inlay depth. All designs with and without ferrule and all inlay depths showed clinically acceptable marginal and internal fit. The conventional endocrown design without ferrule and 2 mm inlay depth showed the lowest surface gap. The pulpal surface showed the highest discrepancy among all groups compared to the other surfaces. Endocrowns without ferrule are more conservative and have higher fracture strength than 1 mm ferrule designs; extending the inlay depth showed a significant increase in fracture resistance of the 1 mm ferrule design, but not for the conventional design without ferrule and 2 mm inlay depth. All groups exhibited a high auspicious fracture strength value for molar endocrown restorations.

Research topics

  • Dental materials and restorations
  • Bone Tissue Engineering Materials
  • Dental Implant Techniques and Outcomes

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.3390/ma17061411

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.