article · Journal of Alloys and Compounds
Detecting aromatic volatile organic compounds (VOCs) like xylene isomers, especially m-xylene, amidst benzene and toluene remains challenging due to their similar structures, boiling points, and overlapping properties. M-Xylene is particularly challenging to identify due to its low reactivity and polarity, often requiring high temperatures that increase power consumption and reduce sensor lifespan, thereby limiting portable and real-time applications. Thus, herein, Ag-decorated SrTiO 3 /MXene heterostructures were synthesized and systematically evaluated to elucidate the influence of Ag incorporation on their structural, optical, and gas-sensing properties. Ag-loading preserved the sheet-like architecture of SrTiO 3 /MXene while inducing notable improvements in microstructure. Structural findings confirmed Ag nanoparticle sizes of ~5–25 nm for 1 wt% and ~15–45 nm for 2 wt% samples. A significant reduction in defect-related electronic states upon Ag addition was observed. Gas-sensing investigations demonstrated that the 1 wt% Ag-loaded sample exhibited a better response toward m-xylene at 100 °C, with a response value of 1.002, a detection limit of 3.1 ppm, and rapid response/recovery times of 15 s/ 25 s, respectively. This enhancement is associated with the increased surface area, stronger catalytic activity, and effective oxygen spillover, which collectively promote the formation of reactive oxygen species and facilitate charge-transfer interactions with m-xylene. Selectivity toward m-xylene was further supported by its electron-rich structure, minimal steric hindrance, and favourable π–π interactions compared to other BTX gases. These findings confirmed that the Ag-modified SrTiO 3 /MXene heterostructure is a capable sensor for low-temperature aromatic VOC detection in complex environments. • Ag-decorated SrTiO 3 /MXene heterostructures were synthesized and evaluated for gas sensing • A significant reduction in defect-related electronic states upon Ag addition was observed. • 1 wt% Ag-loaded sample exhibited a better response toward m-xylene at 100 °C. • A low detection limit and rapid response/recovery times were observed.
This page summarises published work. The authoritative version sits with the publisher.
DOI: 10.1016/j.jallcom.2026.188585
Is something wrong with this record? Report it or request removal.
Discussion
Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.
No discussion yet. Open the first thread.
New to MARATTO™? Create a free account.