MARATTO

article · Scientific Reports

Sustainable high-throughput microwell spectrophotometric methods for avapritinib quality control via charge-transfer complexation

Abstract

Avapritinib (AVA) is a breakthrough targeted therapy as the first potent inhibitor approved for gastrointestinal stromal tumors (GIST) with PDGFRA D842V mutations. It lacks convenient analytical methods for routine quality control. This study addresses this gap by developing and validating two novel, green, high-throughput microwell spectrophotometric methods (MW-SPMs) for AVA quantification in pharmaceutical tablets-representing the first employment of charge-transfer complexation for AVA analysis. The methods exploit rapid charge-transfer complex (CTC) formation between AVA (electron donor) and two π-acceptors: 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) and chloranilic acid (CLA). The reactions, conducted in 96-well plates using only 200 µL total volume, yielded stable colored complexes with absorption maxima at 460 nm and 520 nm for the reactions with DDQ and CLA, respectively. Following ICH-compliant optimization and validation, both methods demonstrate excellent linearity (3.13-100 µg/well for DDQ; 6.25-100 µg/well for CLA), precision (RSD ≤ 1.8%), and accuracy (recoveries: 98.0-101.7%). Job's method confirmed 1:1 stoichiometry, while density functional theory (DFT) uniquely revealed the molecular basis for the stronger binding affinity of DDQ over CLA through dominant π-π stacking and hydrogen-bonding interactions, demonstrating how computational analysis can guide reagent selection in analytical method development. A comprehensive multi-metric sustainability assessment-utilizing ten tools including AES, AGREE, BAGI, RGB, and RAPI-confirmed the methods' excellent greenness (e.g., AES score = 90), superior practicality, and robust analytical performance, achieving a high White Index of 94.2%. With a substantially higher throughput of ~ 500 samples/hour and minimal solvent consumption (200µL/well), the proposed MW-SPMs offers a rapid, sustainable, and cost-effective alternative to conventional chromatographic and spectrofluorimetric techniques for routine pharmaceutical analysis, aligning with multiple United Nations Sustainable Development Goals.

Research topics

  • Advanced Biosensing Techniques and Applications
  • Monoclonal and Polyclonal Antibodies Research
  • Analytical Chemistry and Sensors

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.1038/s41598-026-51872-6

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.