MARATTO

article · ITM Web of Conferences

Study and design of a patch antenna for biomedical applications

202313 citationsOpen accessUniversité Moulay Ismail de Meknes

Abstract

This work presents the performance of a Dual-band patch antenna with L-shaped slot for biomedical applications. The antenna works at 2.4 GHz and 3.33 GHz. A semi-flexible substrate material which is “Taconic TLX (tm)” with a relative dielectric constant, ℇr of 2.55, loss tangent, tan δ of 0.0019 and thickness, h of 0.7 mm has been proposed to be the isolant element of the antenna. The size of the antenna is 60 x 55 mm². The slots in the rectangular radiating patch were introduced to produce the resonant frequencies of 2.4GHz and 3.33GHz. The simulations of the microstrip patch antenna shows the reflection coefficient, S11 of -31.67 dB and -20.25 dB at 2.4 GHz and 3.27 GHz respectively. The proposed antenna shows a peak gain of 5.01 dB at 2.4 GHz. The results were obtained using HFSS (high frequency structured simulator) software.

Research topics

  • Antenna Design and Analysis
  • Wireless Body Area Networks
  • Energy Harvesting in Wireless Networks

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.1051/itmconf/20235203003

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.