MARATTO

article · BMC Chemistry

Stability indicating high performance thin layer chromatography method development and validation for quantitative determination of tetracycline hydrochloride in tetracycline hydrochloride active pharmaceutical ingredient (API) and its dosage forms

202413 citationsOpen accessDebre Markos University

Abstract

Simple, quick, cost-effective, and environmentally friendly analytical methods for quality assurance and control roles for different medicines, including Tetrcyclines, are most significantly needed. Also, different thin layer chromatography (TLC)-based methods for tetracycline identification exist, but high performance thin layer chromatography methods based on modern state- of- the art equipment are still nonexistent. Thus, in this study, analytical method development and verification were done by high performance thin layer chromatography (HPTLC) (using an automated equipment model) using glass plates coated with silica gel 60 F<sub>254</sub> after treating with 10% Na<sub>2</sub>EDTA. Validation was carried out according to International Council for Harmonization (ICH) guidelines. A mobile phase formed from ethyl acetate, acetonitrile, methanol, and 1% aqueous ammonia in the composition of 4.4:19.6:10:6 volume to volume ratio (V/V) was used. R<sub>f</sub> value, percentage recoveries, linearity ranges, limit of detection (LOD), and limit of quantitation (LOQ) for the developed HPTLC method were 0.28, 100.83-106.25%, 160-560 ng/band (r<sup>2</sup> values of 0.9999), 31.9 ng/band, and 96.7 ng/band, respectively. The results of the sample assays conducted using the new method and the United States Pharmacopoeia (USP) high performance liquid chromatography (HPLC) method were 91.59% to 108.3% and 90.83% to 102.85%, respectively. The F test for the aforementioned methods was 2.01, which is smaller than the tabulated F value of 5.05 with 5 degrees of freedom at a 95% confidence range, proving that the newly developed HPTLC and HPLC pharmacopoeial methods can be used interchangeably.The newly developed HPTLC method is easy, economical, specific, accurate, and roboust, thus it can be employed in a range of settings that require quality control and assurance activities of tetracycline hydrochloride (TC-HCl) in bulk and ointment dosage forms.

Research topics

  • Pharmaceutical and Antibiotic Environmental Impacts
  • Analytical chemistry methods development
  • Analytical Methods in Pharmaceuticals

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.1186/s13065-024-01183-6

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.