MARATTO

article · Chemical Papers

Quantitative analysis of organosulphur compounds in crude oil samples using magnetic solid phase extraction based on Au-Fe3O4 adsorbent and gas chromatography with time-of-flight mass spectrometry

20242 citationsOpen accessUniversity of South Africa

Abstract

Abstract This study focused on the development of a magnetic solid phase extraction (m-SPE) method using Au-Fe 3 O 4 as an adsorbent followed by GC-ToFMS analysis for the determination of organosulphur compounds (OSCs) in fuel samples. The m-SPE using Au-Fe 3 O 4 NPs was preferred because of the low toxicity of the adsorbent 1 , high separation efficiency using external magnet 2 and greater extraction selectivity between sulphur and Au atom 3 . The Au-Fe 3 O 4 NPs were characterized using XRD, UV–Vis, TEM, SEM and FTIR. This method was optimized using multivariate analysis based on a two-level full factorial and central composite designs. The conditions which produced optimum efficiency were found to be 150 mg mass of sorbent, 100 µL eluent volume, 50 min extraction time and 6,5 pH of the sample. These optimum conditions showed a relatively low limit of detection in the range of 0.02–0.199nµg/g and limit of quantification of 0.08–0.602 µg/g. Furthermore, a relative standard deviation of triplicates analysis was between 0.8 and 2.3% with good linearity of 0.9816–0.9961. The percentage recovery for thiophene, 3-methylthiophene, benzothiophene and dibenzothiophene ranged from 76 to 95% for the spiked samples. The optimized m-SPE method was then applied in real fuel oil samples. The concentration of thiophene, 3-methylthiophene, benzothiophene and dibenzothiophene in crude oil, gasoline, diesel and kerosene ranged from 0.43–1.94 µg/g, 0.78–1.63 µg/g, 0.95–4.31 µg/g to 1.55–2.09 µg/g, respectively. The m-SPE, followed by GC-ToFMS method, proved to be efficient, inexpensive and an alternative method for OSCs analysis in fuel oils.

Research topics

  • Petroleum Processing and Analysis
  • Analytical chemistry methods development
  • Analytical Chemistry and Chromatography

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.1007/s11696-024-03465-8

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.