MARATTO

article · The Egyptian Journal of Critical Care Medicine

Pulse contour analysis versus transthoracic echocardiography in assessment of cardiac output in patients with low cardiac output syndrome post cardiac surgery

2026Open accessCairo University

Abstract

Low cardiac output syndrome (LCOS) is a critical postoperative complication following cardiac surgery, leading to increased morbidity and mortality. This study aimed to evaluate the reliability of pulse contour analysis (PCA) using the Flotrac EV1000 system compared with transthoracic echocardiography (TTE) for Cardiac output (CO) measurement in LCOS patients. A single-center, prospective observational study was conducted on 50 patients with LCOS post-cardiac surgery. CO was measured using both TTE and PCA. Hemodynamic, clinical, and biochemical parameters were recorded, and correlations between CO measurements and clinical variables were assessed. The study population had a mean age of 52.2 ± 11.3 years, with 68% males and 60% classified as obese. Both PCA and TTE confirmed low cardiac output (PCA: 2.42 ± 0.56 L/min; TTE: 2.48 ± 0.58 L/min) with a very strong correlation between the two methods (r = 0.97, p < 0.001). Cardiac output positively correlated with body size, blood pressure, urine output, and central venous oxygen saturation, while negative correlations were noted with urea, creatinine, and lactate levels. These findings highlight the association between hemodynamic compromise and renal dysfunction in LCOS. Pulse contour analysis provides a reliable, continuous alternative to transthoracic echocardiography for cardiac output monitoring in LCOS patients post-cardiac surgery. Its real-time capability enhances clinical decision-making and supports timely interventions in the ICU setting.

Research topics

  • Hemodynamic Monitoring and Therapy
  • Sepsis Diagnosis and Treatment
  • Ultrasound in Clinical Applications

Sustainable Development Goals

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.1007/s44349-026-00041-9

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.