MARATTO

article · IEEE Sensors Journal

Performance Prediction of a Highly Sensitive Optimized PCF-SPR Biosensor for Cancer Cell Detection Using MLP-Based ANN Model

202512 citationsUniversity of Sousse

Abstract

Recent developments in surface plasmon resonance (SPR) sensors based on photonic crystal fiber (PCF) technology have greatly enhanced sensitivity. Nevertheless, existing configurations often face challenges related to design complexity and real-time application optimization. In this study, we present a straightforward and highly sensitive circular PCF-SPR biosensor tailored for the detection of early-stage cancer cells, with efficient performance across both visible and near-infrared spectrums. Using the Taguchi L<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">27</sub>(3<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">5</sup>) orthogonal array approach, we optimized five critical structural parameters: air hole diameters, pitch, and the thickness of the gold (Au) and titanium dioxide (TiO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub>) layers. The resulting sensor achieved remarkable spectral sensitivity of 18,000 nm/RIU and an amplitude sensitivity of 681.655 RIU<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup>. Designed to function across a wide refractive index range (1.29-1.40), the biosensor is particularly effective for identifying cervical, blood, and skin cancer cells, reaching peak sensitivity of 7,500 nm/RIU for cervical cancer detection. Additionally, performance prediction utilized machine learning techniques, specifically Multiple Linear Regression (MLR) and Multi-Layer Perceptron Artificial Neural Network (MLP-ANN) models. The MLP-ANN model demonstrated superior predictive accuracy, highlighting the potential of artificial intelligence in optimizing biosensor configurations for advanced cancer diagnostics.

Research topics

  • Acoustic Wave Resonator Technologies

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.1109/jsen.2025.3556292

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.