article · BMC Medical Informatics and Decision Making
BACKGROUND: Differentiated thyroid cancer (DTC) is a common endocrine malignancy with rising incidence and frequent recurrence, despite a generally favorable prognosis. Accurate recurrence prediction is critical for guiding post-treatment strategies. This study aimed to enhance predictive performance by refining feature engineering and evaluating a diverse ensemble of machine learning models using the UCI DTC dataset. METHODS: Unsupervised data engineering-specifically dimensionality reduction and clustering-was used to improve feature quality. Principal Component Analysis (PCA) and Truncated Singular Value Decomposition (t-SVD) were selected based on superior clustering metrics: adjusted Rand Index (ARI > 0.55) and V-measure (> 0.45). These were integrated into classification pipelines using Logistic Regression (LR), Support Vector Machine (SVM), Random Forest (RF), K-Nearest Neighbors (KNN), Feedforward Neural Network (FNN), and Gradient Boosting (GB). Model performance was evaluated through bootstrapping on an independent test set, stratified 10-fold cross-validation (CV), and subgroup analyses. Metrics included balanced accuracy, F1 score, AUC, sensitivity, specificity, and precision, each reported with 95% confidence intervals (CIs). SHAP analysis supported model interpretability. RESULTS: The PCA-based LR pipeline achieved the best test set performance: balanced accuracy of 0.95 (95% CI: 0.90-0.99), AUC of 0.99 (95% CI: 0.97-1.00), and sensitivity of 0.94 (95% CI: 0.84-1.00). In stratified CV, it maintained strong results (balanced accuracy: 0.86; AUC: 0.97; sensitivity: 0.80), with consistent performance across clinically relevant subgroups. The t-SVD-based LR pipeline showed comparable performance on both test and CV sets. SVM and FNN pipelines also performed robustly (test AUCs > 0.99; CV AUCs > 0.96). RF and KNN had high specificity but slightly lower sensitivity (test: ~0.87; CV: 0.77-0.80). GB pipelines showed the lowest overall performance (test balanced accuracy: 0.86-0.88; CV: 0.85-0.88). CONCLUSIONS: Dimensionality reduction via PCA and t-SVD significantly improved model performance, particularly for LR, SVM, FNN, RF and KNN classifiers. The PCA-based LR pipeline showed the best generalizability, supporting its potential integration into clinical decision-support tools for personalized DTC management. CLINICAL TRIAL NUMBER: Not applicable.
This page summarises published work. The authoritative version sits with the publisher.
DOI: 10.1186/s12911-025-03018-3
Is something wrong with this record? Report it or request removal.
Discussion
Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.
No discussion yet. Open the first thread.
New to MARATTO™? Create a free account.