MARATTO

article · World Journal of Cardiovascular Diseases

Interdialytic 24-Hours Ambulatory Blood Pressure versus Dialysis Unit Blood Pressure for the Diagnosis of Electrocardiographic-Left Ventricular Hypertrophy in Chronic Hemodialysis Black Patients

20191 citationOpen accessUniversité de Kinshasa (UNIKIN)

Abstract

Background and Aim: In hemodialysis patients, 24-hours interdialytic ABPM better detects TOD than dialysis unit blood pressure. Therefore, the present study was aimed to assess the diagnostic performance of 24-hours ABPM vs. dialysis unit BPs for the diagnosis of ECG-LVH in steady state chronic hemodialysis black patients. Methods: From March 31 to September 30, 2018, interdialytic ABPM was performed after a mid-week hemodialysis session for 24 hours using a Spacelab 90207 ABPM monitor in the non-access arm in 45 stable chronic hemodialysis black patients (age ≥ 20 years, hemodialysis for at least 3 months and informed consent) attending 3 hemodialysis centers in Kinshasa. Ambulatory BP was recorded every 20 minutes during the day (6 AM to 10 PM) and every 30 minutes during the night (10 PM to 6 AM). ECG-LVH was defined using Cornell product criteria. ROC curve method was used to assess the performance of dialysis unit BPs vs. interdialytic 24-hours ABPM in diagnosing ECG-LVH. P 0.05 defined the level of statistical significance. Results: Whatever the method of BP measurement, all the SBP values were related to ECG-LVH with similar AUC and overlapping 95% CI; however, they were not significantly different from each other. 24-hours interdialytic ambulatory SBP (AUC 0.748; 95% CI 0.58 - 0.94) had the highest area under the curve. Conclusion: The present study showed that although all the two BP measurement methods equally detected ECG-LVH, 24-hours ABPM tended to have the highest diagnostic performance.

Research topics

  • Dialysis and Renal Disease Management
  • Blood Pressure and Hypertension Studies
  • Renal function and acid-base balance

Sustainable Development Goals

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.4236/wjcd.2019.911075

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.