MARATTO

preprint

Influence of Roxolid Implant Material on The Implant Stability of Maxillary Implant Retained Overdenture

2024Open accessAin Shams University

Abstract

<title>Abstract</title> Background Long-term success of implant restoration depends on many factors one of them is the sufficient implant stability which is lowered in compromised bone density sites such as the maxilla as it is categorized as type III &amp; IV bone, so searching for a new innovation and updates in implant material and features is very mandatory. So, the aim of this study was to compare between two implant materials (roxolid and traditional titanium) on the primary and secondary stability of implant retained maxillary overdenture. Methods Eighteen completely edentulous patients were selected. All patients received maxillary implant-retained overdentures and lower complete dentures; patients were divided equally into two groups according to the type of implant materials. Group A received a total number of 36 implants made of roxolid material and Group B received a total number of 36 implants made of traditional titanium alloys. Implant stability was assessed using ostell device, the primary implant stability was measured at the day of implant installation however, secondary implant stability was measured after six weeks of implant placement. Paired t-test was used to compare between primary and secondary stability in the same group and an independent t-test was used to compare between the two groups with a significant level &lt; 0.05. Results Independent t-test revealed a significant difference between the two groups with p -value = 0.0141 regarding primary stability and p-value &lt; 0.001 regarding secondary stability, as roxolid implant group was statistically higher stability than titanium group in both. Paired t- test showed a statistically significant difference in roxolid implant group with p-value = 0.0122 however, there was non-statistically significant difference in titanium group with p-value = 0.636. Mann Whitney test showed a significant difference between the two groups regarding amount of change in stability with p value = 0.191. roxolid implant group showed a higher amount of change in stability than the titanium implant group. Conclusion Within the limitation of this study, it could be concluded that: Roxolid implants showed better primary and secondary stability than conventional titanium one in implant retained maxillary overdenture. Trial registration: NCT06334770 at 27-3-2024.

Research topics

  • Dental Implant Techniques and Outcomes
  • Bone Tissue Engineering Materials
  • Dental Radiography and Imaging

Sustainable Development Goals

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.21203/rs.3.rs-4394435/v1

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.