Experimentally Driven Numerical Model of Carbon/Polyaniline-Based Glucose Monitoring Sensors: An Evaluation Using a New Figure of Merit

Abstract

This study presents an experimentally driven numerical model for evaluating carbon/polyaniline (PANI)-based glucose monitoring sensors, focusing on innovative configurations using graphene-PANI and carbon nanotube (CNT)-PANI composites. We performed a thorough analysis of the morphological, electrophysical, and electrical properties of these materials, ultimately leading to the extraction of key electrical parameters for integration into a finite element model (FEM). This model simulates the entire sensor, enabling the estimation of critical performance metrics such as sensitivity, limit of detection (LOD), linearity, and power consumption. Our findings demonstrate that the CNT-PANI configuration significantly outperforms the laser induced graphene (LIG)-PANI electrode, achieving a figure of merit (FOM) of 0.99 compared to 0.62, thanks to its superior electrical conductivity and high surface area, which facilitates enhanced charge transfer and electrochemical reactions. The optimized sensor configurations reveal optimal parameters for LIG-PANI and CNT-PANI, underscoring the trade-offs between conductivity and overall sensor performance. Notably, the CNT-PANI composite exhibits the highest sensitivity of 2778 μA mM<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> cm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-2</sup> and the lowest LOD of 0.09 μM, making it a promising candidate for glucose detection in clinical applications. This work highlights the importance of power consumption in sensor design, with all configurations operating at 0.232 mW, and sets a new benchmark for future glucose monitoring technologies. Finally, the study illustrated a clinical investigation to verify the selectivity and sensitivity of PANI towards various molar concentrations of glucose.

Research topics

  • Electrochemical sensors and biosensors
  • Analytical Chemistry and Sensors
  • Conducting polymers and applications

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.1109/jsen.2025.3570069

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.