article · International Journal of Modelling Identification and Control
The present work establishes a comparison between two controllers based on a backstepping approach for a fuel-cell power system. The load resistance representing the impedance of the dc bus is assumed to be unknown and can change. Besides, the internal fuel-cell voltage is not accessible for measurement. Therefore, to cope with these two issues, two output feedback controllers are designed using a backstepping technique. The first controller uses an integral action while the second one is an adaptive version of the former. It is formally shown using theoretical analysis and simulation that the obtained controllers achieve all control objectives. A comparison between the two controllers shows that, when they are correctly tuned, both behave almost similarly. Nevertheless, we noted the weak supremacy of the adaptive version over the integral version in terms of rapidity. A laboratory prototype is built to show the effectiveness of the proposed control approaches.
This page summarises published work. The authoritative version sits with the publisher.
DOI: 10.1504/ijmic.2023.133141
Is something wrong with this record? Report it or request removal.
Discussion
Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.
No discussion yet. Open the first thread.
New to MARATTO™? Create a free account.