article · ASEAN Journal of Scientific and Technological Reports
Structures made of stainless steel experience a gradual deterioration in their fundamental properties when exposed to both mechanical stress and harsh environmental conditions. This study aims to analyze the impact of cold tensile deformation on the localized roughness corrosion of 304L stainless steel in a 3% NaCl solution, mimicking seawater conditions. Corrosion tests were performed on samples obtained from standardised tensile specimens of the Public Economic Enterprise for the Production of Bolts, Cutlery, and Faucets (BCR) in Boumerdes, Algeria, which had experienced deformation at strain levels of 2.18%, 3.63%, 10.90%, and 16.36%. The results, including corrosion susceptibility, pitting behavior, and repassivation potentials, were evaluated and compared based on the strain. Findings indicate that all measured potentials decrease as the strain increases, except for the roughness potential, which shows a significant decline. This suggests a notable reduction in the material's corrosion resistance with higher deformation levels.
This page summarises published work. The authoritative version sits with the publisher.
DOI: 10.55164/ajstr.v28i5.258484
Is something wrong with this record? Report it or request removal.
Discussion
Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.
No discussion yet. Open the first thread.
New to MARATTO™? Create a free account.