article · Journal of Radioanalytical and Nuclear Chemistry
Abstract There is limited information on utilizing commercially supplied [ 18 F]Fluoride from an off-site cyclotron for the synthesis of radiopharmaceuticals. This study explored the production of the PET hypoxia marker [ 18 F]FMISO, using the Scintomics® GRP module and distantly produced [ 18 F]Fluoride, which lacks published data. A radiochemical yield of 27.4 ± 3.6% ( n = 5) and high radiochemical purity were achieved in synthesis time of 48 min. The [ 18 F]FMISO met all Ph. Eur. standards, demonstrating the consistency and reliability of the module in generating a clinical-grade radiopharmaceutical using off-site produced [ 18 F]Fluoride, but available patient doses were severely limited.
This page summarises published work. The authoritative version sits with the publisher.
DOI: 10.1007/s10967-024-09734-w
Is something wrong with this record? Report it or request removal.
Discussion
Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.
No discussion yet. Open the first thread.
New to MARATTO™? Create a free account.