article · Case Studies in Thermal Engineering

Enhancing PVT performance with triangular tubes: A numerical study on Bi-fluid cooling efficiency gains

Abstract

Hybrid PVT systems are emerging as a key solution to improve solar energy utilization by simultaneously generating electricity and recovering thermal energy. This study presents a numerical investigation of a hybrid photovoltaic-thermal (PVT) system enhanced by a bi-fluid cooling mechanism, combining water and air to optimize thermal and electrical performance. The system integrates 16 triangular tubes beneath a 54 cm × 120 cm PV panel (4 × 8 cells), with water circulating at 0.0025 kg/s and natural air flow for enhanced cooling. Simulations were conducted using meteorological data from a representative day in Algeria, from 7:00 to 18:00, with solar irradiance varying from 114.71 to 995.57 W/m 2 and ambient temperatures ranging from 306.05 to 318.13 K. The bi-fluid cooling system demonstrated superior performance, achieving an average thermal efficiency of 41.10 % - an 80.65 % improvement over conventional PVT systems. Peak thermal power outputs reached 292.53 W (water) and 92.28 W (air), with maximum outlet temperatures of 327.98 K (water) and 322.85 K (air). Electrical efficiency improved to 14.93 % while maintaining PV module temperatures at an average of 326.26 K. The system's total thermal power output averaged 200.42 W throughout the day. These results highlight the effectiveness of combined water-air cooling in Algerian conditions, where high solar irradiance and ambient temperatures typically challenge PV performance. The study provides valuable insights for optimizing PVT systems in similar semi-arid climates, demonstrating significant potential for practical solar energy applications. The proposed bi-fluid PVT configuration offers a scalable and efficient pathway for solar energy harvesting in hot regions, with strong implications for sustainable building applications. • A novel bi-fluid PVT system with 16 triangular tubes was numerically analyzed. • Combining constant water flow (0.0025 kg/s) with passive air convection for hybrid cooling. • Achieving 41.10 % thermal efficiency—an 80.65 % improvement over conventional systems. • Electrical efficiency reached 14.93 % while maintaining average PV temperature at 326.26 K. • First to integrate triangular geometry with bi-fluid cooling under real Algerian climate data.

Research topics

  • Solar Thermal and Photovoltaic Systems
  • Building Energy and Comfort Optimization
  • Solar Energy Systems and Technologies

Sustainable Development Goals

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.1016/j.csite.2025.106831

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.