article · Water Science
This study experimentally investigates the effect of soil aeration using vertical perforated air vents on aquifer recharge efficiency in sandy soils. Although soil aeration has been proposed as a promising technique, there is a lack of experimental quantification of the optimal aerated surface area required to significantly enhance infiltration and recharge performance. Therefore, a laboratory-scale sand tank model was developed to evaluate recharge behavior under different aerated surface area ratios (2.25%–13.51%). Hydraulic conductivity and water level responses were systematically measured using falling-head tests and piezometers. The results reveal a non-linear relationship between aerated area and recharge efficiency, with a critical threshold around 9% coverage and a maximum average water level reduction of 34% at 13.51% coverage. These findings provide quantitative guidance for optimizing aeration design in artificial aquifer recharge systems under controlled laboratory conditions.
This page summarises published work. The authoritative version sits with the publisher.
DOI: 10.1007/s44533-026-00034-8
Is something wrong with this record? Report it or request removal.
Discussion
Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.
No discussion yet. Open the first thread.
New to MARATTO™? Create a free account.