MARATTO

article · Dental and Medical Problems

Effect of the scanner type on the marginal gap and internal fit of two monolithic CAD/CAM esthetic crown materials: An in vitro study

20245 citationsOpen accessBritish University in Egypt

Abstract

BACKGROUND: The durability of indirect restorations is significantly influenced by marginal adaptation and internal fit. The use of computer-aided design/computer-aided manufacturing (CAD/CAM) with digital impressions has reduced dental prosthesis fabrication errors, improving the long-term survivability of the restorations. OBJECTIVES: The present study assessed the impact of intraoral and extraoral scanning methods on the marginal adaptation and internal fit of 2 different types of monolithic crowns manufactured using CAD/CAM. MATERIAL AND METHODS: A total of 40 three-dimensional (3D) resin-printed dies were randomly assigned to 2 groups based on the type of crown material (n = 20 per group). Each group was divided into 2 subgroups (n = 10 per group) according to the die-scanning technique: subgroup A, scanned using the intraoral scanner (IOS) Primescan; and subgroup B, scanned using the extraoral scanner (EOS) inEos X5. The digitized photos were converted into a 3D virtual crown design using CAD software. The internal discrepancy values, and the marginal gap between the 3D resin-printed die and the crown were assessed using a ×50 digital microscope. The data was checked for normality with the Kolmogorov-Smirnov test, and the Mann-Whitney U test was used to compare the tested groups. The collected data was analyzed at a significance level set at p < 0.05. RESULTS: The different scanning techniques used had a statistically significant effect on the vertical marginal gap and the internal fit [μm] (p < 0.05). As far as the crown materials are concerned, BRILLIANT Crios showed a significantly higher marginal gap as compared to Tetric CAD when scanned with inEos X5 (p = 0.004), whereas the differences were insignificant with regard to the internal fit (p > 0.05).The crown parameters tested with both scanning systems were within the clinically acceptable ranges. CONCLUSIONS: Scanning methods and crown materials had an impact on the internal fit and vertical marginal gap of monolithic crowns.

Research topics

  • Dental materials and restorations
  • Dental Implant Techniques and Outcomes
  • Dental Research and COVID-19

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.17219/dmp/185895

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.