MARATTO

article · Chemosensors

Eco-Friendly Nanocellulose Optical Chemosensor Immobilized with ADOL for Mercury Detection in Industrial Wastewater

20261 citationOpen accessSuez University

Abstract

A novel chemosensor has been developed for the accurate and sensitive detection of Hg2+ ions in industrial wastewater. This sensor uses a stick-like nanocellulose architecture synthesized via a green method. The unique morphology and surface area of nanocellulose make it an ideal mesoporous substrate for immobilizing the chromophore 1-(benzothiophenyl)-3-(benzooxazolyl)-2-((4-bromophenyl)diazenyl)propane-1,3-dione (azo-dione ligand, ADOL). Comprehensive characterization of the fabricated chemosensor and its nanocellulose base was carried out using FTIR, SEM, TEM, BET surface area, and XRD to evaluate their structural and morphological properties. Spectrophotometric parameters, including pH, response time, selectivity, and sensitivity, were extensively optimized to ensure optimal sensing performance, enabling detection of Hg2+ at very low concentrations. Method validation was performed in accordance with ICH (International Council for Harmonisation) guidelines, confirming the reliability of the sensor in terms of limit of detection (LOD), limit of quantification (LOQ), linearity, and precision. The spectrophotometric method achieved a highly sensitive LOD of 9.07 µg L−1. Moreover, the ADOL chemosensor demonstrated excellent reusability, maintaining performance over five cycles following regeneration with 0.1 M thiourea, underscoring its sustainability. Finally, the sensor exhibited outstanding performance in detecting Hg2+ across various industrial wastewater samples, highlighting its practical applicability, exceptional selectivity, and high sensitivity for real-world environmental monitoring.

Research topics

  • Molecular Sensors and Ion Detection
  • Carbon and Quantum Dots Applications
  • Polydiacetylene-based materials and applications

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.3390/chemosensors14020045

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.