article · Energy Conversion and Management
• Energy and daylighting performance assessment of a novel multifunctional window. • MFWs provide electricity and heat, along with reducing the building’s cooling load. • CFD and daylighting tools model an office with MFW for comprehensive analysis. • Using MFWs, south-facing orientations offer net electricity savings of 33 % to 75 %. • Fenestrations with 50 % PV coverage achieve the balance between daylighting levels and energy generation . Leveraging the entire solar spectrum in building facades is crucial to achieving zero-energy buildings concept. This study presents a novel multifunctional window (MFW) that combines photovoltaic laminates with a selective liquid filter (SLF) in a mono-glazing system. For a comprehensive assessment of the energy and daylight performance of a standard office equipped with MFW, it has been developed an innovative model integrating thermal, electrical, optical, and energy aspects, utilizing both CFD and daylighting analysis tools. The net electricity benefit (NEB) serves as a key metric to evaluate the energy performance of MFWs compared to traditional windows. Additionally, Useful Daylight Illuminance (UDI), Illuminance Uniformity (U o ), and Daylight Glare Probability (DGP) are employed to predict the annual daylight performance of MFW under various Photovoltaic-to-Space Ratios (PVSR). The findings reveal that using MFWs significantly reduces office cooling energy consumption, ranging from 41 % to 73 % in south-oriented buildings compared to standard glazing. Despite increased artificial lighting consumption (ALC) with PVSR, MFWs significantly improve the NEB due to higher energy generation and reduced cooling loads. MFWs with 50 % PVSR also enhance daylight distribution uniformity and minimize potential glare, while balancing PVSR at 50 % optimizes energy generation and ensures ample illumination in office spaces. Further, the levelized cost of electricity generation (LCOE el ) for the MFW ranges from $0.166 to $0.143/kWh e .
This page summarises published work. The authoritative version sits with the publisher.
DOI: 10.1016/j.enconman.2024.119325
Is something wrong with this record? Report it or request removal.
Discussion
Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.
No discussion yet. Open the first thread.
New to MARATTO™? Create a free account.