article · Scientific Reports
Abstract The research aim is to clarify the effect of courtyard placement, the ratio between length and width, and courtyard orientation on energy consumption in residential buildings in hot and dry climates, to seek planning and designing alternatives for new cities and new residential complexes that are consistent with the environment and climate and save the consumption of energy used in the buildings. The research method was conducted through Design Builder software for simulation purposes. The reference model with the 157.25 m 2 which accommodates a central square courtyard measuring 5 m × 5 m, on a residential building model in the New Valley Governorate of Kharga City, Egypt. The courtyard simulation is aimed to determine Less energy consumption inside the different case studies, in 9 courtyard placements The studied alternatives for Courtyard Placement, are (the center of the building, sub facades, and main facades). The different ratios are (1:1, 1.25:1, 1.5:1–1.75:1, 2:1, 2.25:1, 2.5–1). The longitudinal axis of the Courtyard has been oriented to the east–west direction for all placements, and north–south direction for all placements. Also, (orientation angle is Zero), it offered the percentages of better and worst cases in each position of the courtyard. The research findings suggest that the best Placement of the Courtyard that achieved the highest rate of saving of energy consumed inside the used building model was at the southwestern façade, with a saving rate of 18.73%. Then, the Placement of the Courtyard at the northwestern and southeastern facades with a saving rate of 17.91%, with a length-to-width ratio (2.5:1) if the longitudinal axis of the Courtyard is oriented in the north–south direction, Through the study, we conclude that the placement and orientation of the courtyard and its regular formation have contributed to rationalizing energy consumption in residential buildings, the study reached some important standards that could represent a methodological framework for designing contemporary residential buildings with an energy-efficient inner courtyard.
This page summarises published work. The authoritative version sits with the publisher.
DOI: 10.1038/s41598-024-60487-8
Is something wrong with this record? Report it or request removal.
Discussion
Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.
No discussion yet. Open the first thread.
New to MARATTO™? Create a free account.