article · Results in Materials
The corrosion behaviour of two cobalt-based coatings (ULTIMET™ and STELLITE™ 6) with zero, 0.3 and 0.6 wt% ruthenium were studied and compared with two cobalt-based bulk alloys (ULTIMET™ and STELLITE™ 6B) in synthetic mine water (pH values of 6, 3 and 1) using potentiodynamic polarisation. The coatings demonstrated wider ranges of passivation behaviour (from −250 mV to 750 mV) than the bulk alloys. The corrosion potential became more positive and the active-passive transition reduced with increased Ru. The best coating was STELLITE™ 6 with 0.6 wt% Ru, which exhibited the lowest corrosion rates: 3.6 μm/y at pH 6 and 6.4 μm/y at pH 3.
This page summarises published work. The authoritative version sits with the publisher.
DOI: 10.1016/j.rinma.2024.100546
Is something wrong with this record? Report it or request removal.
Discussion
Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.
No discussion yet. Open the first thread.
New to MARATTO™? Create a free account.