Abstract

BACKGROUND: Newer generation ultrathin strut stents are associated with less incidence of target lesion failure (TLF) in patients undergoing percutaneous coronary intervention (PCI) in the short term. However, its long-term effect on different cardiovascular outcomes remains unknown. OBJECTIVES: We aim to identify the effects of newer-generation ultrathin-strut stents vs. standard thickness second-generation drug-eluting stents (DES) on long-term outcomes of revascularization in coronary artery disease. METHODS: We searched PubMed, Web of Science, Cochrane Library databases, and Scopus for randomized controlled trials (RCTs) and registries that compare newer-generation ultrathin-strut (< 70 mm) with thicker strut (> 70 mm) DES to evaluate cardioprotective effects over a period of up to 5 years. Primary outcome was TLF, a composite of cardiac death, target vessel myocardial infarction (TVMI) or target lesion revascularization (TLR). Secondary outcomes included the components of TLF, stent thrombosis (ST), and all-cause death were pooled as the standardized mean difference between the two groups from baseline to endpoint. RESULTS: We included 19 RCTs and two prospective registries (103,101 patients) in this analysis. The overall effect on the primary outcome was in favor of second-generation ultrathin struts stents in terms of TLF at ≥ 1 year, ≥ 2 years, and ≥ 3 years (P value = 0.01, 95% CI [0.75, 0.96]), P value = 0.003, 95% CI [0.77, 0.95]), P value = 0.007, 95% CI [0.76, 0.96]), respectively. However, there was no reported benefit in terms of TLF when we compared the two groups at ≥ 5 years (P value = 0.21), 95% CI [0.85, 1.04]). Some of the reported components of the primary and secondary outcomes, such as TLR, target vessel revascularization (TVR), and TVMI, showed the same pattern as the TLF outcome. CONCLUSION: Ultrathin-strut DES showed a beneficial effect over thicker strut stents for up to 3 years. However, at the 5-year follow-up, the ultrathin strut did not differ in terms of TLF, TLR, TVR, and TVMI compared with standard-thickness DES, with similar risks of patient-oriented composite endpoint (POCE), MI, ST, cardiac death, and all-cause mortality.

Research topics

  • Coronary Interventions and Diagnostics
  • Cardiac Imaging and Diagnostics
  • Cardiac and Coronary Surgery Techniques

Sustainable Development Goals

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.1186/s40001-024-01949-7

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.