article · Asian Journal of Advanced Research and Reports
Advances in AI, physics-informed modelling, and Digital Twin technologies offer the potential to enhance predictive maintenance, asset-integrity assessment, and energy management within oil and gas processing systems. However, these frameworks are most useful when they are based on a common data source, use a consistent model configuration, and are tested under a defined set of operating conditions. This study presents and evaluates an AI-assisted, physics-informed DT for an integrated crude distillation unit and hydrotreating system based on a 180-day synthetic operating dataset. The framework integrates a bidirectional Long Short-Term Memory (BiLSTM) network for equipment-anomaly detection and remaining useful life (RUL) estimation, a Physics-Informed Neural Network (PINN) to predict the wall thickness of process piping, and the Non-Dominated Sorting Genetic Algorithm II (NSGA-II) to optimise energy. During the independent test period, the precision and recall of the BiLSTM were 0.9654 and 0.9941, respectively, with a false-alarm rate of 3.85% and a RUL mean absolute error of 6.24 days. The RMSE and MAE for the independent evaluation period of the wall-thickness were 0.00585 mm and 0.00526 mm, respectively, for the PINN. It was found that a feasible operating condition could be obtained from NSGA-II using a load setpoint of 0.88 and a recycle fraction of 0.02. The Digital Twin strategy reduced simulated electricity consumption by 2.24% and fuel-energy consumption by 2.14%, equivalent to an estimated reduction of 452.67 t CO₂e over the 180-day simulation period when compared to the defined baseline. The results show that predictive maintenance, physics-informed asset-integrity prediction and energy optimisation can be integrated computationally within a single Digital Twin framework in a viable manner. The results do not constitute field validation, as the data are synthetic and the energy and environmental estimates are model-based. Further assessment using plant-specific sensor, maintenance, inspection, and energy-consumption data is needed before industrial implementation.
This page summarises published work. The authoritative version sits with the publisher.
DOI: 10.9734/ajarr/2026/v20i91456
Is something wrong with this record? Report it or request removal.
Discussion
Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.
No discussion yet. Open the first thread.
New to MARATTO™? Create a free account.