MARATTO

article · Journal of Pharmaceutical and Biomedical Analysis

A stability indicating RP-HPLC-UV assay method for the simultaneous determination of hydroquinone, tretinoin, hydrocortisone, butylated hydroxytoluene and parabens in pharmaceutical creams

202413 citationsOpen accessMenoufia University

Abstract

Multicomponent drugs are medications that combine two or more active pharmaceutical ingredients in a single dosage form. These dosage forms improve the patient compliance, reduce the risk of drug interactions, and simplify dosing regimens. However, quality control of these multicomponent dosage forms can be challenging, especially if the final product contains four or more ingredients that are active (comprise stabilizers, preservatives, excipients, and other components). This problem can be more pronounced if the excipients can interfere with the analysis. In this work, a stability indicating assay method was developed and validated (according to the ICH International Guidelines) for the simultaneous determination of hydroquinone (HQ), tretinoin (TRT), hydrocortisone (HCA), butylated hydroxytoluene (BHT), methyl paraben (MP) and propyl paraben (PP) in commercially available pharmaceutical creams. The proposed method is based on gradient elution using X-Bridge C18 (150 × 4.6 mm, 5 µm) column with a flow rate of 1 mL/min. The linear ranges (μg/mL) were 240-560 for HQ, 24-56 for MP, 132-308 for HCA, 6-14 for PP, 12-28 for BHT, 6.6-15 for TRT. During the validation process, the intra- and interday precision and trueness (evaluated as recovery) were found to be below 2.0% and between 100-102%, respectively. System suitability tests (SST) allow validating the herein proposed procedure specifically for pharmaceutical and industrial applications. SST test shows that the reported procedure fulfill with the Guidelines, allowing excellent separation of the analytes with very sensitive, accurate (precise and true) and reproducible quantitation of each analytes. The method was successfully applied in forced degradation studies of the six analytes. Specifically, acid degradation slightly affected HCA and BHT (91% recovery), while alkaline degradation drastically reduced HCA recovery (5.5%) and moderately affected BHT (85%). Photodegradation primarily influenced TRT quantity, and oxidative degradation intensified the BHT peak (130%).

Research topics

  • Analytical Methods in Pharmaceuticals
  • Analytical Chemistry and Chromatography
  • Antibiotics Pharmacokinetics and Efficacy

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.1016/j.jpba.2024.116021

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.