article · Nuclear Analysis
This work aims to study the response function of a 2″×2″ NaI(Tl) scintillation detector using Monte Carlo simulations. A precise mathematical model of the NaI(Tl) scintillator was developed using both FLUKA and GAMOS Monte Carlo simulation software. The photon pulse height distributions of the NaI(Tl) without influence of its energy resolution, obtained with FLUKA and GAMOS codes, were converted into a real NaI(Tl) response function using the necessary conversion process. Spectral characteristics such as full-energy peak efficiency, energy resolution, peak-to-Compton ratio, and peak-to-total ratio were investigated by simulation at different gamma-ray energy obtained from 109 Cd, 137 Cs, 54 Mn, 65 Zn, and 60 Co sources. The simulated spectra from the GAMOS code were consistent with those generated by the FLUKA code. Additionally, the comparison between simulated results and experimental data demonstrated good agreement. The validation of the computational models used for the NaI(Tl) detector in both FLUKA and GAMOS software was successfully achieved, confirming the accuracy of the simulations in replicating the detector's response.
This page summarises published work. The authoritative version sits with the publisher.
DOI: 10.1016/j.nucana.2024.100138
Is something wrong with this record? Report it or request removal.
Discussion
Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.
No discussion yet. Open the first thread.
New to MARATTO™? Create a free account.