MARATTO

article · Scientific Reports

A barrel theory-based optimization of stochastic PV-DG integration in radial distribution networks under load and solar uncertainties

20261 citationOpen accessZagazig University

Abstract

The increasing penetration of photovoltaic distributed generation (PV-DG) in Radial Distribution Systems (RDSs) plays a vital role in achieving sustainable energy transition objectives; however, the inherent uncertainty associated with solar irradiance and load demand poses significant challenges to optimal planning and operation. This paper presents a stochastic optimization framework for PV-DG allocation in RDSs using the Barrel Theory-Based Optimizer (BTO). Uncertainties in solar irradiance and load demand are explicitly modeled using appropriate probability density functions and efficiently represented through a higher-order Point Estimate Method (PEM), which captures the essential statistical characteristics with a limited number of representative scenarios. The proposed framework simultaneously optimizes the location and capacity of PV-DG units to minimize real power losses and enhance voltage profile performance while ensuring system operational constraints are satisfied. The effectiveness of the proposed approach is validated on the 85-bus and the IEEE 118-bus RDSs, where the BTO exhibits superior convergence characteristics and enhanced solution robustness when compared with several benchmark optimization techniques, including the well-established Differential Evolution Algorithm (DEA), the recent Crocodile Ambush Optimization (CAO, 2025), and the Schrödinger Optimizer Algorithm (SOA, 2025). For the 85-bus RDS, the impact of integrating different numbers of PV units is systematically investigated. Simulation results confirm that the proposed BTO-based stochastic planning strategy significantly improves energy efficiency, voltage regulation, and loss reduction, thereby enhancing the overall sustainability of the RDS. For the 85-node RDS, the BTO achieves a noticeable reduction in average real power losses, outperforming DEA, CAO, and SOA by 2.55%, 4.10%, and 6.74%, respectively, when three PV units are installed. Additionally, for the case of four PV units, the proposed BTO yields even greater improvements, with loss reductions of 5.12%, 7.50%, and 14.12%, respectively, compared with the same benchmark algorithms. Furthermore, for five PV units, the BTO achieves much greater reduction, outperforming DEA, CAO, and SOA by 13.05%, 6.45%, and 32.31%, respectively, when three PV units are installed.

Research topics

  • Optimal Power Flow Distribution
  • Electric Vehicles and Infrastructure
  • Electric Power System Optimization

Sustainable Development Goals

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.1038/s41598-026-49415-0

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.